Merchandise Description
DS Sequence Dry CZPT Vacuum Pump
Characteristics
1.Exhaust Route Is Quick, Reduce The Deposition Of Reactants.
Evaluating with other varieties of dry vacuum pump,DENAIR screw vacuum pump has the shortest gasoline route in the vacuum pump and that could reduce the contamination of procedure gas. CZPT rotors can perform as a powder transmission system,we operates well even there has heaps of contamination inside of the pump.
two.The Optimal CZPT CZPT , The Pump Efficiency.
Patented rotor profile can give rotor excellent sealing consequences thus a larger clearance is allowable in among.Pump rotor wesring and rotor jam by the process contamination can be diminished by larger allowable clearcance.
three.Easy Composition, Low Fault Charge And Straightforward Upkeep
Screw sort vacuum is composed by a pair of screw rotor and isolation plates are necessary in different amongst rotors and isolation plates can also be averted.Overhaul CZPT dry pump is a lot simpler than other kind of dry pump,so the erpair time is shorter and the price is saver.
four.Microcomputer Operation, Remote Checking, Considerate CZPT
Microprocessor controller supplies heaps of pump parameters for operating position checking.Pump can be simply operated and monitored by the operation panel.Distant management computer software can aid the CZPT er keep an eye on the pump managing standing remotely.
DS Vacuum Pump CZPT Curve
Advantages
1.Specific cooling liquid cooling, to steer clear of the cooling h2o might lead to corrosion to the hull.
two.Cell procedure interface, handy procedure Screen and the true work of vacuum pump and can be chosen to each languages, according to the true shut to the CZPT er.
three.Capture the CZPT connector, safe and practical.
4.The nitrogen gas heater, make the vacuum pump is more suitable for CVD, PECVD and other semiconductor strategy procedure.
five.The manage indicators and interaction sign interface, distant checking was carried out on the vacuum.
Software
1.The wellness treatment sector.
two.Lights market.
three.A selection of analytical instruments.
4.Electronics, semiconductor business.
five.The CZPT sector.
six.Refrigeration sector.
Complex Prameters
Type | Unit | DS180 | DS250 | DS360 | DS540 | DS720 | |||||
50Hz | 60Hz | 50Hz | 60Hz | 50Hz | 60Hz | 50Hz | 60Hz | 50Hz | 60Hz | ||
Pumping pace | m3/hr | one hundred eighty | 216 | 250 | three hundred | 360 | 432 | 540 | 650 | 720 | 850 |
L/min | 3000 | 3600 | 4200 | 5000 | 6600 | 7920 | 9000 | 10800 | 12000 | 14400 | |
L/S | 50 | 60 | 70 | 84 | 110 | 132 | one hundred fifty | 180 | 200 | 240 | |
Extreme stress | mbar | .02 | .01 | .02 | .01 | .02 | .01 | .02 | .01 | .02 | .01 |
Torr | .015 | .0075 | .015 | .0075 | .015 | .0075 | .015 | .0075 | .015 | .0075 | |
Pa | 2 | 1 | 2 | one | two | one | two | 1 | two | 1 | |
Power | kW | seven.five | 7.five | seven.five | seven.five | eleven | fifteen | eighteen.five | 18.5 | 22 | 22 |
Speed | RPM | 2900 | 3550 | 2900 | 3550 | 2900 | 3550 | 2900 | 3550 | 2900 | 3550 |
Inlet diameter | mm | 65 | 80 | 100 | 150 | 150 | |||||
Outlet diameter | mm | 40 | 40 | 65 | 65 | 65 | |||||
Gear chamber oil content | L | 0.85 | 0.85 | 1.40 | 2.00 | 2.00 | |||||
Cooling water | L/min | 2.50 | 2.60 | 2.80 | 3.00 | 4.00 | |||||
gal/min | 0.67 | 0.70 | 0.75 | 0.80 | 1.07 | ||||||
Weight | Kg | 295 | 350 | 480 | 520 | 680 | |||||
Sounds degree | dB(A) | 75 | 78 | 81 | 85 | 86 | |||||
Place temp | ºC | 5-forty | |||||||||
Maximum permissible humidity | 90% |
Type | Unit | DSV250 | DSV360 | DSV540 | DSV720 | DSV1200 | |||||
50Hz | 60Hz | 50Hz | 60Hz | 50Hz | 60Hz | 50Hz | 60Hz | 50Hz | 60Hz | ||
Pumping pace | m3/hr | 250 | 300 | four hundred | 480 | 580 | seven-hundred | 800 | 960 | 1200 | 1440 |
L/min | 4200 | 5000 | 6600 | 7920 | 9600 | 11500 | 13200 | 15800 | 19800 | 23700 | |
L/S | 70 | 84 | one hundred ten | 132 | one hundred sixty | 192 | 220 | 264 | 330 | 396 | |
Extreme stress | mbar | .02 | .01 | .02 | .01 | .02 | .01 | .02 | .01 | .02 | .01 |
Torr | .015 | .0075 | .015 | .0075 | .015 | .0075 | .015 | .0075 | .015 | .0075 | |
Pa | 2 | 1 | two | 1 | 2 | 1 | two | one | 2 | 1 | |
Electrical power | kW | five.5 | 7.5 | seven.5 | eleven | 11 | fifteen | 15 | eighteen.five | 22 | 22 |
Pace | RPM | 2900 | 3550 | 2900 | 3550 | 2900 | 3550 | 2900 | 3550 | 2900 | 3550 |
Inlet diameter | mm | 65 | 80 | 100 | 150 | 150 | |||||
Outlet diameter | mm | 40 | 40 | 65 | 65 | 65 | |||||
Gear chamber oil material | L | 0.eighty five | 0.eighty five | 1.four | 2 | 2 | |||||
Cooling h2o | L/min | 2.50 | 2.50 | 2.60 | 2.80 | 3.50 | |||||
gal/min | 0.67 | 0.67 | 0.70 | 0.75 | 0.94 | ||||||
Bodyweight | Kg | 295 | 350 | 480 | 520 | 680 | |||||
Sounds level | dB(A) | 72 | 73 | 75 | 78 | 80 | |||||
Area temp | ºC | 5-40 | |||||||||
Maximum permissible humidity | ninety% |
Observe:
1.The sum of oil shown earlier mentioned is for reference only and is typically fluoride and mineral oil. The system is equipped with pump oil and grease oil.
2.The amount of cooling h2o is primarily based on the ambient temperature of 30ºC and the cooling h2o inlet temperature of 20ºC . The use of circulating h2o will vary, and the h2o force will be .fifteen-.2Mpa.
*) Specs are subject matter to change with out prior notice
About CZPT
FAQ
Q1: Are you manufacturing unit or trade business?
A1: We are manufacturing facility.
Q2: What the precisely tackle of your manufacturing facility?
A2: Our firm is positioned in No. 6767, Tingfeng Rd. Xihu (West CZPT ) Dis.n District, ZheJiang 201502, CZPT
And CZPT manufacturing unit is positioned in No.386,YangzhuangBang Street,Pingxing Rd.,Xindai City,HangZhou,ZHangZhoug Province, CZPT
Q3: Warranty terms of your equipment?
A3: Two a long time warranty for the equipment and technological help in accordance to your demands.
This fall: Will you offer some spare areas of the devices?
A4: Yes, of program.
Q5: How CZPT will you just take to set up manufacturing?
A5: 380V 50HZ we can shipping the products inside ten times. CZPT electric power or other coloration we will supply within 22 times
Q6: Can you take CZPT orders?
A6: Yes, with expert design group, CZPT orders are hugely welcome.
Radial blowers are designed for large conveying volumes. The customer’s volume movement needs can be exactly modified by implies of a frequency converter built-in into the motor. Radial blowers use quick and non-contact rotating impellers, producing them put on and maintenance-totally free.